We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.

Professional Medical Equipment Supplier - Yuesen Med Professional Medical Equipment Supplier - Yuesen Med

Hot Products

YSX500D 50kW DR system set up and put into service in Cambodia.

YSENMED YSX500D 50kW digital x-ray system has been successfully set up and put into service in a hospital in Cambodia.

YSX056-PE serving as a vehicle-mounted x-ray in the Philippines

YSX056-PE 5.6kW portable x-ray unit has been adapted to fit on a truck, to provide mobile x-ray examination service for remote communities in the Philippines.

X Ray Machine  To  Zimbabwe

x ray machine, 50KW x ray machine

Microscope To Malawi

Achromatic objectives: 4X、10X、40X(S), 100X(S、Oil) Wide field eyepiece: WF10X(WF16X for option) Eyepiece head: Sliding binocular head inclined at 45° Stage: Double layer mechanical stage size 140X140mm, moving range 75X45mm Focusing: Coaxial coarse and

X-ray machine introduction

Views : 957
Author : Yuesen Med
Update time : 2015-04-22 08:00:00
x-ray machine is a device to generate X-rays, which is mainly composed of X-ray tube and an X-ray power supply component, while the X-ray tube and a cathode filament (Cathod) and anode target (Anode) and a vacuum glass tube, X-ray power supply High voltage and filament can be divided into two parts, power.

x-ray machine of the physical effects:

1.
X-ray machine Function

High frequency inverter technology with low-dose exposure to obtain high-definition video, high-power, high kV, mA load large output to meet the needs of the body photography, short transient exposure, eliminate motion artifacts, easily capture image information, APR functions to achieve different anatomical imaging condition easily select, select the ionization chamber AEC automatic control functions to achieve photographic exposure.
 
A, x-ray radiation output stable
High slope and low output voltage ripple, high power, high kV, short photography, can effectively reduce the internal organs caused by the imaging blur peristaltic, greatly improve the image quality.
 
B, x-ray machine high quality X-ray
DC component is high, the imaging time is short; high exposure accuracy, repeatability imaging with minimal dose to obtain clear images and rich clinical diagnostic information.
 
C, x-ray machines effectively reduce radiation damage
Significantly reduce the stray rays reduce radiation intensity subjects and operators, the same projection conditions, lower than the frequency machine skin dose by 60%.
 
D, x-ray machines to achieve computer control
High degree of automation, automatic control functions expand, more convenient operation, strong system expansion upgrade capability, the generator is smaller than traditional power frequency, higher efficiency, and significantly reduced void rays.

2.X-ray machine Classification and Scope:


Medical x-ray machines used in hospitals for diagnostic X-ray intervention, chest X-ray, film, gastrointestinal barium meal, double contrast barium, check gastrointestinal disease, colon disease inspection, examination of urinary tract disease, biliary tract "T" type angiography, Check the hepatobiliary situation.
 
Medical x-ray machine can be divided according to the intended use diagnostic and therapeutic x-ray machine x-ray machines into two categories
 
A.diagnostic x-ray machine
 
1, according to the structure:
(1) a portable x-ray machine (2) mobile x-ray machine (3) fixed x-ray machine

 
2, according to the output power divided:
A, a small x-ray machine: tube current 50 mA, the maximum tube voltage is 90 kV;
B, neutral X-ray machine: 100,400 mA tube current, the tube voltage of 100 kV up to 125 kV or;
C, large X-ray machine: the maximum tube current of 500 mA or more tube voltage 125 kV or 150 kV;
 
3, according to the scope of points (1) integrated x-ray machine (2) special x-ray machine
 
B.the treatment of x-ray machines
1, contact: therapeutic ill skin surface or shallow body cavity. 10 kV to 60 kV;
2, surface treatment machine: quality large area of ​​the patient's skin or superficial. 60 kV to 140 kV;
3, deep therapy machine: deep tissue therapy patients, 180 kV to 250 kV.

 

 
Related News
Read More >>
Kenyan distributor sets up YSX500D DR system and considers re-purchase. Kenyan distributor sets up YSX500D DR system and considers re-purchase.
May .01.2025
Our Kenyan distributor has successfully set up the YSX500D 50kW digital x-ray system in a hospital, and considers purchasing another 32kW x-ray system.
YSFPD-M1717V VET flat panel detector helps digitize the x-ray in a Peruvian vet clinic YSFPD-M1717V VET flat panel detector helps digitize the x-ray in a Peruvian vet clinic
Apr .30.2025
With the professional after-sales assistance from YSENMED team, Peruvian vet has managed to upgrade his mobile analog x-ray system with YSFPD-M1717V VET wilress flat panel detector and the images come out clear and highly satisfactory.
The well functioning SonoScape S50 ultrasound system makes Dr. Roger happy The well functioning SonoScape S50 ultrasound system makes Dr. Roger happy
Apr .29.2025
Dr. Roger is so excited to receive the SonoScape S50 color doppler ultrasound system, and he can't wait to put it into practice.
Why Do Babies Need Infant Radiant Warmers? Why Do Babies Need Infant Radiant Warmers?
Apr .26.2025
One crucial piece of equipment in neonatal care is the infant radiant warmer. But why exactly do babies need these warmers? Let's dive into the world of infant care and explore this important topic.